TBM5-TERM

Written by easterow on September 15, 2015

TBM5-TERM

tbm-5-term

The TBM5-TERM dry contact control module is designed to provide on-off control of one circuit by means of a touch-sensitive input.

Rated for loads of 0.5 amps at 125VAC or 1 amp at 30VAC/30VDC.

Input Current 3mA Off, 12mA On (24VDC or 24VAC).

Number of operations under rated electrical load is 200,000 minimum.

Faceplate and Touchbolt™ Assembly not included with standard TBM5-TERM unit.

U.L. listed termination boxes.

Units can be C.U.L. listed, consult factory if required.

Units requiring C.U.L. listing must be specified at time of order.